3S~32S 10A-60A Lithium-ion Battery Low Current best bms for lifepo4 batteries ternary lithium battery low current series
· Electric Current
Lithium ion Battery BMS from 15A~60A
· String Number
Lithium ion Battery BMS from 3S~24S
· Demand
Daly BMS can be customized with special Specifications
Item | Description | Specifications (Lithium ion low-current) | |||||
Model | Current | 15A | 20A | 30A | 40A | 50A | 60A |
Discharge | Continue discharge current | 15A | 20A | 30A | 40A | 50A | 60A |
Sparkle current | 65±10A | 65±10A | 100±20A | 165±30A | 200±30A | 200±30A | |
Inner Resistance | Main circuit conduct inner resistance | ≤20mΩ | ≤20mΩ | ≤10mΩ | ≤10mΩ | ≤10mΩ | ≤10mΩ |
Charge | Charge voltage | Series*4.2V | |||||
Charge current | 10A | 10A | 20A | 30A | 40A | 50A | |
Over charge protection | Over charge detect voltage | 4.25±0.05V | |||||
Over charge protection delay | 1S | ||||||
Balance | Balance detect voltage | 4.18V | |||||
Balance release voltage | 4.18V | ||||||
Balance current | 30±5A | ||||||
Over discharge protection | Over discharge detect voltage | 2.7±0.1A | |||||
Over discharge detect delay | 1S | ||||||
Over discharge release voltage | 3.0±0.1V | ||||||
Over current protection | Over current detect delay | 1MS | |||||
Short circuit protection | Short circuit protection condition | Short circuit of external load | |||||
Short circuit detect delay | 250uS | ||||||
Short circuit protection release condition | Off load | ||||||
Temp Protect | Temperature-protect | Charging: <-5℃ or >50℃, discharging >70℃ | |||||
Self-consumption | Working current | 100uA | |||||
Sleeping current (when in discharge) | 20uA | ||||||
Working Temp | Temp range | -20~70℃ | |||||
Storage Temp | Temp range | -40~80℃ |